BrightLine® long-pass filter set, optimized for mCherry and other like fluorophores

Semrock Part Number: mCherry-40LP-A-NTE-ZERO

IDEX Part Number: S-000502  /

Semrock

This filter set is ideal for use with the monomeric fluorescent protein mCherry. It also works well for broader orange-to-red fluorophores like MitoTracker Red. It is optimized to provide high brightness.

  • Price Not Available.
  • Each
    US Domestic pricing – contact your local distributor for other currency list prices
  • Price Not Available.
  • 1,573.00 USD Each
    US Domestic pricing – contact your local distributor for other currency list prices
  • 0.00
    0.00
  • Notify me when available

FF01-562/40-25

FL-004456 / 0

Out of Stock Backordered In Stock
  • Tavg > 93% 542 – 582 nm
  • Center Wavelength of 562 nm and GMBW of 40 nm
  • FWHM of 45.5 nm

FF593-Di03-25x36

FL-007026 / 0

Out of Stock Backordered In Stock
  • Dichroic Beamsplitter with edge at 593 nm
  • Ravg > 98% 350 – 585 nm
  • Tavg > 93% 601 – 950 nm
  • Flatness / RWE: Standard Epi-fluorescence

FF01-593/LP-25

FL-009103 / 0

Out of Stock Backordered In Stock
  • Filter with 50% edge at 601 nm
  • Tavg > 93% 604 – 1100 nm

1 of 1

This set is mounted in a Nikon NTE Fluorescence Filter Holder, which is compatible with Nikon microscopes TE 2000, 50i, 55i, 80i, 90i, Eclipse Ti, Ni, and Ci series, and any using the Epi-fluor Illuminator.

Filter Role Filter Size Maximum Thickness
Exciter (Diameter)25.0 mm5.0 mm
Emitter (Diameter)25.0 mm3.5 mm
Dichroic (L × W)25.2 mm × 35.6 mm1.1 mm
(Can accept 2 mm dichroic)
TopicDescription
Cleaning Optical FiltersInstructions for cleaning hard coated optical filters
Filter ReliabilityCompares the performance and reliability of hard coated filters to traditional soft-coated filters and provides information about the testing standards for Semrock filters
Working with Optical Density Tables to describe the relationship between OD and transmission with tips for quickly calculating OD
What is Pixel Shift, and how does the Semrock ZERO option help? Why Pixel Shift degrades multicolor fluorescence imaging performance, and how the ZERO™ option mitigates this for Avant and BrightLine filter sets.
Optimized – Filter set is specifically optimized for that fluorophore.
Compatible – Should result in nearly ideal performance in most situations.
Acceptable – Actual performance is dependent on specific experimental conditions.
Fluorophore Peak Excitation Wavelength(nm) Peak Emission Wavelength(nm) Compatibility Display on Plot above
2-dodecylresorufin-lipid 582 595
5-carboxynapthofluorescein (pH 10) 555 615
5-ROX (carboxy-X-rhodamine) 578 604
7-AAD (7-aminoactinomycin D) 548 648
Alexa Fluor® 568 579 603
Alexa Fluor® 594 590 618
AsRed 2 576 592
ATTO 565 563 592
ATTO 590 594 624
ATTO 594 601 624
BOBO™-3 570 605
BODIPY TR-X phallacidin 590 621
Calcium Crimson 589 609
Carboxynaphthofluorescein 599 674
CellTrace BODIPY TR methyl ester 598 625
CellTracker Red CMTPX 586 614
ChlorophyllA 480 650
Cy3.5™ 578 591
DDAO 648 657
DsRed-Express 556 584
dTomato 556 582
DY-590 582 599
DyLight 594 593 618
Ethidium bromide 518 603
Ethidium homodimer 527 617
FluoSpheres Crimson fluorescent microspheres 620 646
FluoSpheres Red fluorescent microspheres 577 607
FM 4-64 505 725
HcRed1 588 618
HCS LipidTOX Red neutral lipid stain 582 616
HCS LipidTOX Red phospholipidosis 584 608
HiLyte Fluor™ 594 592 616
KFP-Red 575 599
LDS 751 560 711
LIVE-DEAD Fixable Red Dead Cell Stain 595 613
LysoTracker Red 573 592
mApple 566 594
mCherry 587 610
MitoTracker™ Red 578 598
mKate2 588 633
mPlum 589 649
mRFP 555 583
mRFP1 584 700
mRuby 558 605
mStrawberry 574 596
Nile red-phospolipid 553 637
PerCP 490 677
Propidium Iodide (PI) 305 617
Qdot® 605 Nanocrystals 300 602
Qdot® 625 Nanocrystals 300 621
Qdot® 655 Nanocrystals 300 654
Qdot® 705 Nanocrystals 300 702
Qdot® 800 Nanocrystals 300 792
ReAsH-CCPGCC 592 606
Red 580 580 603
Rhodamine Red-X 573 591
SNARF (carboxy) 514 Excitation pH9 576 638
SNARF-1 488nm (ph 6.0) 548 586
SNARF-1 488nm (ph 9.0) 576 638
SNARF-1 514nm (ph 6.0) 549 587
SNARF-1 514nm (ph 9.0) 576 638
SpectrumRed 587 615
Sulforhodamine 101-EtOH 578 593
Texas Red dextran 592 613
Texas Red DHPE 584 608
Texas Red® 592 614
TurboFP635(Katushka) 591 638
X-Rhod-1 Indicator 580 601
YOYO-3 611 631

Related Products

FF01-562/40-25

FL-004456 / 0

Out of Stock Backordered In Stock
  • Tavg > 93% 542 – 582 nm
  • Center Wavelength of 562 nm and GMBW of 40 nm
  • FWHM of 45.5 nm

FF593-Di03-25x36

FL-007026 / 0

Out of Stock Backordered In Stock
  • Dichroic Beamsplitter with edge at 593 nm
  • Ravg > 98% 350 – 585 nm
  • Tavg > 93% 601 – 950 nm
  • Flatness / RWE: Standard Epi-fluorescence

FF01-593/LP-25

FL-009103 / 0

Out of Stock Backordered In Stock
  • Filter with 50% edge at 601 nm
  • Tavg > 93% 604 – 1100 nm

1 of 1

This set is mounted in a Nikon NTE Fluorescence Filter Holder, which is compatible with Nikon microscopes TE 2000, 50i, 55i, 80i, 90i, Eclipse Ti, Ni, and Ci series, and any using the Epi-fluor Illuminator.

Filter Role Filter Size Maximum Thickness
Exciter (Diameter)25.0 mm5.0 mm
Emitter (Diameter)25.0 mm3.5 mm
Dichroic (L × W)25.2 mm × 35.6 mm1.1 mm
(Can accept 2 mm dichroic)
TopicDescription
Cleaning Optical FiltersInstructions for cleaning hard coated optical filters
Filter ReliabilityCompares the performance and reliability of hard coated filters to traditional soft-coated filters and provides information about the testing standards for Semrock filters
Working with Optical Density Tables to describe the relationship between OD and transmission with tips for quickly calculating OD
What is Pixel Shift, and how does the Semrock ZERO option help? Why Pixel Shift degrades multicolor fluorescence imaging performance, and how the ZERO™ option mitigates this for Avant and BrightLine filter sets.