You have been successfully removed from the product notification list.
| Topic | Description |
| Cleaning Optical Filters | Instructions for cleaning hard coated optical filters |
| Filter Reliability | Compares the performance and reliability of hard coated filters to traditional soft-coated filters and provides information about the testing standards for Semrock filters |
| Working with Optical Density | Tables to describe the relationship between OD and transmission with tips for quickly calculating OD |
| What is Pixel Shift, and how does the Semrock ZERO™ option help? | Why Pixel Shift degrades multicolor fluorescence imaging performance, and how the ZERO™ option mitigates this for Avant and BrightLine filter sets. |
This set is mounted in an Evident Scientific (Olympus) OMF Fluorescence Filter Holder, which is compatible with the AX (AX70), BX2 (BX41, BX50, BX51, BX60, BX61, BX50/51WI, BX60/61WI), and IX2 Series (IX50, IX51, IX70, IX71, IX81) of Evident Scientific (Olympus) microscopes.
| Filter Role | Filter Size | Maximum Thickness |
| Exciter (Diameter) | 25.0 mm | 5.0 mm |
| Emitter (Diameter) | 25.0 mm | 5.0 mm |
| Dichroic (L × W) | 26 mm x 38 mm | 1.5 mm |
| Link | Description |
| Request a Drawing | Looking for an optical filter drawing file for this product? Request one now! |
| Request Custom Optical Filters | Contact us today to start a conversation about custom optical filters. |
| Access Optical Filter Warranty | Find our warranty in our Terms & Conditions of Sale. |
| Semrock Optical Filters RoHS Certificate | RoHS, stands for Restriction of Hazardous Substances. The current RoHS Directive currently restricts the use of ten substances. |
| Semrock Optical Filters REACH Certificate | REACH is a regulation of the European Union, adopted to improve the protection of human health and the environment from the risks that can be posed by chemicals, while enhancing the competitiveness of the EU chemicals industry. |
| Download Optical Filters 101 Guide | Find an in-depth overview of optical filter principles, specifications, and applications. Request a digital copy of this guide now. |
| Request Clean Filter Checklist Poster | Looking to clean your optical filters? Need instructions? Request a printed copy of our Clean Filter Checklist Poster. |
| Fluorophore | Peak Excitation Wavelength(nm) | Peak Emission Wavelength(nm) | Compatibility | Display on Plot above |
|---|---|---|---|---|
| 5-carboxynapthofluorescein (pH 10) | 555 | 615 |
|
|
| 5-TAMRA (5-carboxytetramethylrhodamine, pH 7.0) | 542 | 568 |
|
|
| 6-carboxyrhodamine 6G | 525 | 555 |
|
|
| 6-JOE | 520 | 548 |
|
|
| Alexa Fluor® 514 | 518 | 543 |
|
|
| Alexa Fluor® 532 | 534 | 553 |
|
|
| Alexa Fluor® 546 | 556 | 572 |
|
|
| Alexa Fluor® 555 | 553 | 565 |
|
|
| Alexa Fluor® 633 | 631 | 647 |
|
|
| Alexa Fluor® 647 | 653 | 668 |
|
|
| Alexa Fluor® 660 | 663 | 691 |
|
|
| Alexa Fluor® 680 | 679 | 702 |
|
|
| Amplex UltraRed peroxidation product (pH 7.5) | 568 | 581 |
|
|
| APC | 651 | 660 |
|
|
| APC (Allophycocyanin) | 651 | 660 |
|
|
| ATTO 520 | 516 | 538 |
|
|
| ATTO 532 | 501 | 545 |
|
|
| ATTO 550 | 553 | 576 |
|
|
| ATTO 565 | 563 | 592 |
|
|
| ATTO 620 | 618 | 642 |
|
|
| ATTO 633 | 629 | 658 |
|
|
| ATTO 635 | 635 | 658 |
|
|
| ATTO 647 | 644 | 670 |
|
|
| ATTO 647N | 645 | 668 |
|
|
| ATTO 655 | 663 | 683 |
|
|
| ATTO 680 | 680 | 700 |
|
|
| BODIPY 650/665-X | 646 | 664 |
|
|
| BODIPY TMR-X | 544 | 573 |
|
|
| BODIPY TR-X (MeOH) | 544 | 573 |
|
|
| Calcium Orange | 589 | 609 |
|
|
| Carboxynaphthofluorescein | 599 | 674 |
|
|
| Cy3.5â„¢ | 578 | 591 |
|
|
| Cy3â„¢ | 554 | 566 |
|
|
| Cy5.5â„¢ | 672 | 690 |
|
|
| Cy5â„¢ | 649 | 666 |
|
|
| DDAO | 648 | 657 |
|
|
| Dendra2 (Red) | 554 | 569 |
|
|
| DiD (DiIC18(5)) - Lipophilic Tracer | 648 | 670 |
|
|
| DiI | 551 | 569 |
|
|
| DsRed | 559 | 583 |
|
|
| DsRed-Express | 556 | 584 |
|
|
| dTomato | 556 | 582 |
|
|
| DY-530 | 537 | 560 |
|
|
| DY-630 | 634 | 656 |
|
|
| DY-675 | 675 | 699 |
|
|
| DyLight 549 | 553 | 569 |
|
|
| DyLight 649 | 651 | 673 |
|
|
| DyLight 680 | 676 | 705 |
|
|
| Eosin | 525 | 546 |
|
|
| Ethidium bromide | 518 | 603 |
|
|
| Ethidium homodimer | 527 | 617 |
|
|
| FluoSpheres Crimson fluorescent microspheres | 620 | 646 |
|
|
| FluoSpheres Dark Red fluorescent microspheres | 656 | 683 |
|
|
| FluoSpheres Orange fluorescent microspheres | 540 | 559 |
|
|
| Gold 525 | 521 | 551 |
|
|
| Gold 550 | 551 | 564 |
|
|
| HCS CellMask Red cytoplasmic | 622 | 644 |
|
|
| HCS LipidTOX Deep Red neutral lipid stain | 635 | 652 |
|
|
| HiLyte Fluorâ„¢ 555 | 550 | 566 |
|
|
| HiLyte Fluorâ„¢ 647 | 649 | 673 |
|
|
| HiLyte Fluorâ„¢ 680 | 688 | 702 |
|
|
| IRDye 680 NHS Ester | 683 | 710 |
|
|
| IRDye 700Phosphoramidite | 691 | 699 |
|
|
| KFP-Red | 575 | 599 |
|
|
| LDS 751 | 560 | 711 |
|
|
| LIVE-DEAD Fixable Far Red Dead Cell Stain | 653 | 668 |
|
|
| LOLO-1 | 568 | 580 |
|
|
| Magnesium Orange | 550 | 574 |
|
|
| mApple | 566 | 594 |
|
|
| Merocyanine 540 | 559 | 579 |
|
|
| mHoneyDew | 478 | 562 |
|
|
| MitoTrackerâ„¢ Deep Red | 641 | 662 |
|
|
| MitoTrackerâ„¢ Orange | 551 | 575 |
|
|
| mKO | 549 | 559 |
|
|
| mOrange | 546 | 562 |
|
|
| mOrange2 | 551 | 565 |
|
|
| mRFP | 555 | 583 |
|
|
| mRuby | 558 | 605 |
|
|
| mStrawberry | 574 | 596 |
|
|
| mTangerine | 568 | 585 |
|
|
| Nile blue-EtOH | 631 | 660 |
|
|
| Nile red-triglyceride | 510 | 583 |
|
|
| OFP | 547 | 567 |
|
|
| Orange 552 | 552 | 574 |
|
|
| pHrodoâ„¢, succinimidyl ester | 560 | 587 |
|
|
| POPO-3 | 533 | 574 |
|
|
| PO-PRO-3 | 539 | 570 |
|
|
| Pro-Q Diamond | 556 | 583 |
|
|
| Qdot® 565 Nanocrystals | 300 | 564 |
|
|
| Qdot® 585 Nanocrystals | 300 | 588 |
|
|
| Qdot® 705 Nanocrystals | 300 | 702 |
|
|
| Red 650 | 649 | 665 |
|
|
| Resorufin | 571 | 584 |
|
|
| Rhod-2 | 553 | 577 |
|
|
| Rhodamine phalloidin | 558 | 575 |
|
|
| R-phycoerythrin (PE) | 565 | 576 |
|
|
| SNARF-1 488nm (ph 6.0) | 548 | 586 |
|
|
| SNARF-1 514nm (ph 6.0) | 549 | 587 |
|
|
| SpectrumFRed (Far Red) | 650 | 673 |
|
|
| SpectrumGold | 530 | 556 |
|
|
| SpectrumOrange | 554 | 587 |
|
|
| SYTO 59 | 622 | 644 |
|
|
| SYTO 60 | 650 | 681 |
|
|
| SYTO 61 | 618 | 650 |
|
|
| SYTO 82 | 540 | 559 |
|
|
| SYTOX Orange | 547 | 570 |
|
|
| SYTOX Red-DNA | 640 | 658 |
|
|
| Tetramethylrhodamine dextran | 554 | 582 |
|
|
| TO-PRO-1 | 515 | 531 |
|
|
| TO-PRO-3 | 642 | 657 |
|
|
| TOTO-1 | 514 | 531 |
|
|
| TOTO-3 | 642 | 661 |
|
|
| TRITC (Tetramethylrhodamine) | 552 | 578 |
|
|
| TurboRFP | 553 | 573 |
|
|
| VIC | 530 | 550 |
|
|
| Vybrant DyeCycle Orange | 519 | 563 |
|
| Topic | Description |
| Cleaning Optical Filters | Instructions for cleaning hard coated optical filters |
| Filter Reliability | Compares the performance and reliability of hard coated filters to traditional soft-coated filters and provides information about the testing standards for Semrock filters |
| Working with Optical Density | Tables to describe the relationship between OD and transmission with tips for quickly calculating OD |
| What is Pixel Shift, and how does the Semrock ZERO™ option help? | Why Pixel Shift degrades multicolor fluorescence imaging performance, and how the ZERO™ option mitigates this for Avant and BrightLine filter sets. |
This set is mounted in an Evident Scientific (Olympus) OMF Fluorescence Filter Holder, which is compatible with the AX (AX70), BX2 (BX41, BX50, BX51, BX60, BX61, BX50/51WI, BX60/61WI), and IX2 Series (IX50, IX51, IX70, IX71, IX81) of Evident Scientific (Olympus) microscopes.
| Filter Role | Filter Size | Maximum Thickness |
| Exciter (Diameter) | 25.0 mm | 5.0 mm |
| Emitter (Diameter) | 25.0 mm | 5.0 mm |
| Dichroic (L × W) | 26 mm x 38 mm | 1.5 mm |
| Link | Description |
| Request a Drawing | Looking for an optical filter drawing file for this product? Request one now! |
| Request Custom Optical Filters | Contact us today to start a conversation about custom optical filters. |
| Access Optical Filter Warranty | Find our warranty in our Terms & Conditions of Sale. |
| Semrock Optical Filters RoHS Certificate | RoHS, stands for Restriction of Hazardous Substances. The current RoHS Directive currently restricts the use of ten substances. |
| Semrock Optical Filters REACH Certificate | REACH is a regulation of the European Union, adopted to improve the protection of human health and the environment from the risks that can be posed by chemicals, while enhancing the competitiveness of the EU chemicals industry. |
| Download Optical Filters 101 Guide | Find an in-depth overview of optical filter principles, specifications, and applications. Request a digital copy of this guide now. |
| Request Clean Filter Checklist Poster | Looking to clean your optical filters? Need instructions? Request a printed copy of our Clean Filter Checklist Poster. |
FL-004687